53 / 72
HBC-series V7 LV+MV
Internal Black Box (flying recorder)
– data logger
For correct using o
f controller’s Black Box, set requested value for „Record period“ (
P71
). You can choice more quickly record with more details
but shorter record time (each 10 ms, i.e. 100× per second, record time ca 1,2 minutes) or slower and longer record (each 100 ms, i.e. 10× per
second, record time ca 12 minutes).
Don´t remember set correct number of motor poles for correct rpm value, respectively also gear ratio and tires diameter for correct computing
of car speed of rpm on the mechanical gear box output.
Current version record first 12 minutes of flying (run) respectively 1,2 minutes for quick record. Record automatically stopped after this time.
You can also switch the record for the last 12 minutes running the motor (it is always saved the last 12 minutes)
– record don´t stopped.
Record start when throttle is moved from STOP position after controller turn-on.
Using an external module
LBB_RT
be extended recording time to the order of weeks. If this module is connected, data is automatically stored
in it.
(§NA)
When you want read recorded data, necessary connect Controller to PC and start program Controller 2.
Choice button „
History
“ and push „
Read history
“.
The data reading from the controller are displayed simultaneously to a graph. Chart can be zoom in a separate window (better alternative). Use
the icons in the upper right corner you can select individual parameters to the graph. Each variable can be assigned to the left or right axis gra-
ph (different scales). The curves associated to the right or left vertical axis, whose properties can be adjusted, as appropriate, may be wearing
points for better orientation.
At the same time can be selected in the graph (displayed) up to 9 different variables. Graph can be zoomed, and select part and magnified,
magnified graph can move, save to a file in
xls
format, which is currently stored and parameter settings. Also, it can be stored in
hdf
format,
which you can always read back into the program and view the graph. To work with chart are available as an option similar to load data from
the controller.
Note
: In order to store all data, including parameter settings,
you must save the data to a file while the controller
is turn-on
!
Recorded data
see "Data stored in the record to an internal Black Box" to other sides.
Choice
History
Read History
Graph to separate window