57 / 72
HBC-series V7 LV+MV
Monitoring (display data in real time)
If you need monitor the values of individual variables and data in real time on a PC monitor (not telemetry, which currently has limited options
for imaging), it is appropriate to use the "Monitoring" data. This allows you to watch all the variables as in the graph (as well as for reading data
recorded Black Box) and the numerical values in separate box also.
To start watching this data, you must:
1)
set in the controller parameter
P71
(
Internal BlackBox record period
) on "
Monitoring enabled
“
2)
turn-off the controller, disconnect USBCOM 4(i) from the controller
3)
turn-on the controller
4a) wait for the initial melody (if
P4
is set to "
Programmed limits
" and that you have correctly programmed input signal limits)
OR
4b) Make sequence to "
Start with automatic throttle limits
" (in case
P4
is set to "Automatic limits") and wait to the initial melody
5)
connect USBCOM 4(i) to the controller
6)
select the "
Monitoring
“
7)
press the button "
Start
“
8)
wait for completion of the initial communication with the controller
Now you can watch real-time data. Selecting data in the graph is done as in the case of Black Box.
Likewise, zooming, navigating in a graph, etc. In addition, a separate window with the numerical va-
lues of individual variables is available. Logs can be saved to files, graph picture also.
Monitored data:
They are the same as the data stored in the BlackBox, see previous page ("
“).
Display the value of variables
(parameters) in real time
(separate window)
Battery internal volatge
Main bus volatge
Peak current
Monitoring Start
Save to file
Save graph as picture
MONITORING select