Control CS 320 FU / Rev.A 1.01 – 49
Function
Description
Adjustment
options
Factory setting
SPD. UP
MX *
Acceleration time between starting command and MX SPEED CL. frequency.
Only applies for CLOSING direction of door travel.
0.1 – 5.0 s
2.0 s
SLO. DO.
MX *
Deceleration time between Brake point CL2 and SPEED CLOSE frequency.
Only applies for CLOSING direction of door travel.
* Parameters appear only after programming Brake point CL.2.
0.1 – 5.0 s
2.0 s
SPEED UP
SKS
Acceleration time after reversal of direction until SPEED OPEN/CLOSE frequency.
Applies for both directions of door/gate travel and activation of closing edge safety
device.
0.1 – 1 s
0.5 s
SLOW DO.
SKS
Delay time between activating the SKS closing edge safety device and stopping the
system.
Applies for both directions of door/gate travel and activation of closing edge safety
device.
0.1 – 1 s
0.1 s
SPEED UP LB
Acceleration time after reversal of direction until SPEED OPEN/CLOSE frequency.
Applies for both directions of door/gate travel and activation of photocell.
0.1 – 5.0 s
0.5 s
SLOW DOWN
LB
Delay time between activating the photocell and stopping the system.
Applies for both directions of door/gate travel and activation of photocell.
0.1 – 5.0 s
0.5 s
SLOW DO.
STOP
Delay time between the stop command / reaching an end position and stopping the
system.
Applies for both directions of door/gate running.
0.0 – 5.0 s
0.5 s
RES.INVERTER
Resets all parameters of the frequency converter (factory default setting).
ON
OFF
OFF
MOTOR V
Nominal motor voltage.
100 - 500 V
230 V
MOTOR I
Nominal motor current.
1 – 9.9 A
5.1 A
MOTOR P
Nominal motor current.
100 – 5000 W
550 W
MOTOR PHI
Motor power factor (cosine phi).
0 – 1
0.69
MOTOR HZ
Nominal motor frequency.
10 – 100 Hz
50 Hz
MOTOR RPM
Nominal motor rpm.
NOTICE:
The motor rating data must comply with the data on the type plate.
100 – 5000
min
-1
1370 min
-1
MOTOR HZ
MIN
The minimum value to which the operating frequency of the motor can be set.
10 – 50 Hz
10 Hz
MOT.HZ MAX
The maximum value to which the operating frequency of the motor can be set.
50 – 100 Hz
87 Hz
BRAKE DELAY
Causes delayed brake release following a starting command. Prevent the door/gate
from sagging when it starts from an intermediate position.
0 - 500 ms
50 ms
BOOST CONT.
Constant voltage boost relative to the output frequency.
At low output frequencies, the effective resistance values of the winding can no
longer be neglected in order to maintain the motor flux.
To compensate voltage drops, hold the load and/or maintain the magnetisation, the
inverter output voltage can therefore be boosted using this parameter.
0 – 250 V
50 V