32 – Control CS 320 FU / Rev.A 1.01
Control CS 320 FU / Rev.A 1.01 – 33
EN
RES. INVERTER parameter
Reset all parameters of the frequency inverter to the factory
settings. All other settings remain intact.
➔
„8.7 RESET the frequency inverter settings“
8.5
8.5 RESETTING the controller with
RESETTING the controller with
LCD monitor
LCD monitor
Changing to the INPUT operating mode
Press (P) button until INPUT appears.
Press and hold the buttons (+) and (–) simultaneously for
more than 2 seconds to activate the input.
Resetting the controller
Press the buttons (+/–) until the RESET parameter appears.
The value stands at “OFF”.
Press the button (+) until MOD3 appears.
Press (P) button to start the RESET.
The system runs through the initialisation phase and all
connected safety components and the limit position system
are automatically taught.
Change to adjustment mode
➔
„7.4 Setting the electronic limit position system via the
LCD monitor“
Change to automatic mode
Press (P) button until AUTOMATIC appears.
8.6
8.6 RESETTING the controller without
RESETTING the controller without
LCD monitor
LCD monitor
Interrupt the supply voltage.
Press and hold the circuit board buttons (P) and (–) at the
same time.
Switch the supply voltage back on.
Press and hold the circuit board buttons (P) and (–) at the
same time until the red LED (H6) flashes rapidly.
Release the circuit board buttons (P) and (–).
The system then runs through the initialisation phase (approx.
60 seconds).
During initialisation, it is not possible to program or operate
the system.
After initialisation is complete, the limit positions are deleted
and all parameters are reset to factory settings.
8.7
8.7 RESET the frequency inverter settings
RESET the frequency inverter settings
Change to input mode
Press the (P) button until INPUT appears.
Press and hold the buttons (+) and (-) simultaneously for
more than 2 seconds to activate the input.
Perform a reset
Press the (+/-) buttons until the RES.INVERTER parameter
appears.
The value stands at “OFF”.
Press the (+) button until “ON” appears.
Press the (P) button to start the RESET.
The initialisation phase runs and all settings on the frequency
inverter are reset to factory settings.
The settings must now be performed again.
Change to automatic mode
Press the (P) button until AUTOMATIC appears.
Содержание CS 320 FU
Страница 1: ...EN Control CS 320 FU Rev A 1 01 1 Operating Instructions Control CS 320 FU ...
Страница 74: ...74 Control CS 320 FU Rev A 1 01 ...
Страница 75: ...EN Control CS 320 FU Rev A 1 01 75 ...
Страница 76: ... 185580 ...