18 – Control CS 320 FU / Rev.A 1.01
Control CS 320 FU / Rev.A 1.01 – 19
5.10 Connection of closing edge protective
device 1
With first commissioning and after a RESET the system of
the closing edge protective device is automatically detected
and programmed. If no closing edge system is connected,
the input is requested every time the power is switched on
again until a closing edge system has been detected. With a
subsequent change, the respective system must be selected
via a parameter setting in the INPUT operating mode. In the
case of light barriers with a test function, this must be
set manually.
➔
Optoelectronic closing edge protective device (OSE)
Parameter SKS = MOD1
+
-
1
2
3
4
5
6
7
8
9
12
11
10
X4
WH
GN
BN
5.10 / 1
Legend:
WH White
GN Green
BN Brown
Electrical closing edge protection (8.2 kOhm)
Parameter SKS = MOD2
8k2
1
2
3
4
5
6
7
8
9
12
11
10
X4
5.10 / 2
Pneumatic closing edge protection (DW)
Parameter SKS = MOD3 / testing automatically active
+
-
1
2
3
4
5
6
7
8
9
12
11
10
X4
5.10 / 3
Installation