EN
Control CS 320 FU / Rev.A 1.01 – 59
Display
Meaning
Condition
SKS 4 /
SAFE. 4
(optionally)
Closing edge protective device 4
(8.2kΩ or photo-sensor)
Radio transmission system channel 2
OPEN or CLOSE direction
Display dependent on MOD selected at
parameter SKS 4.
SKS 4 with MOD 2-3
SAFE. 4 with MOD 4
ON:
System is closed.
OFF:
System is interrupted (fault).
—:
Not activated.
IMPULS
Command button / input IMPULS
(X3 / 7+8)
ON:
Button is actuated / input is active.
OFF:
Button is not actuated / input is not active.
TIMER
Week timer (pluggable)
ON:
Timer is active.
OFF:
Timer is not active.
LIGHT BARR.
Light barrier 1
(X4 / 1-4)
ON:
Light barrier signal is OK.
OFF:
Light beam interrupted or light barrier defective.
LIGHT BARR. 2
Light barrier 2
Connection at input 1
(X4 / 9+10)
ON:
Light barrier signal is OK.
OFF:
Light beam interrupted or light barrier defective.
SAFETY CIRC.
Safety circuit 1
Emergency stop systems of door system
ON:
Safety circuit is closed.
OFF:
Safety circuit is interrupted.
STOP
Command button STOP (cover keypad)
ON:
Button is not actuated.
OFF:
Button is actuated.
ROT FIELD
Shows the currently set rolling direction
of the drive
RIGHT:
Setting for a right rotating field.
LEFT:
Setting for a left rotating field.
CYCLE
Door cycle counter
Display of the door cycles that have run through:
1 x open + 1 x CLOSE = 1 cycle
Counting only takes place when the end switch-off points have each been reached.
SERVICE
Service alarm function
Setting via parameter SERVICE and
PIN no. 2
OFF:
Service display not active.
0 – 99999: Service display is active.
Display of the remaining door cycles up to the service message.
AWG
Position information of the absolute
value encoder
Display of the currently transferred value.
C.STOP
HALT/STOP counter
Shows how often the door was stopped. Either through activation of a safety device,
in case of direct direction reversal by a run command or by a direct STOP/HALT
command.
C.OPENED
Counter for top limit position
Shows how often the top limit position was approached.
C.O.BTN
Counter for OPEN commands
Number of all incoming OPEN commands through command devices, sensors and
safety devices (e. g. light barrier).