METAL-FACH
Heating Technology
39
Suggested boiler output settings
(User)
For correct, trouble-free and efficient boiler operation it is recommended to operate the boiler at 80% of its
nominal output and to set the boiler temperature at minimum 60oC. It is also recommended to install a mixing
valve.
Power Parameter
14
16
19
20
28
34
38
50
75
100
150
200
Feeder interlock
5
5
5
5
5
5
5
5
5
5
5
5
Feeder cycle (ON+OFF)
20
20
20
20
20
20
20
20
20
20
20
20
Feeding in cycle-ON
22
25
29
31
43
53
58
28
42
56
53
70
Pre-feed
25
25
25
25
25
25
25
15
15
15
15
15
Ignition
0
0
0
0
0
0
0
0
0
0
0
0
igniter
3
3
3
3
3
3
3
3
3
4
4
4
Fire test
3
3
3
3
3
3
3
2
3
3
2
2
Starting power
60
60
60
60
60
60
60
60
60
60
60
60
Afterburning
2
2
2
2
2
2
2
2
2
2
2
2
Boiler capacity (kW)
14
16
19
20
28
34
38
50
75
100
150
200
Blower 100%
12
12
12
12
12
15
15
15
20
25
70
5
Blower 80%
11
11
11
11
11
13
13
13
18
22
60
65
Blower 60%
10
10
10
10
10
11
11
11
16
20
50
55
Blower 40%
9
9
9
9
9
9
9
9
14
18
40
45
Blower 20%
8
8
8
8
8
8
8
8
12
16
30
35
Firing power
9
9
9
9
9
9
9
9
9
9
12
12
Afterburning
12
12
12
12
12
12
12
12
12
12
12
12
Содержание SEG BIO
Страница 1: ......
Страница 2: ......
Страница 46: ...METAL FACH Heating Technology 44 ...
Страница 52: ...METAL FACH Heating Technology 50 ...
Страница 54: ...METAL FACH Heating Technology 52 ...
Страница 56: ...METAL FACH Heating Technology 54 ...
Страница 63: ......
Страница 64: ......