The first start-up of the boiler
If you have performed all the steps presented above, you can proceed to the first activation of the boiler.
Putting the boiler out
In case of a planned longer standstill of the boiler, set the control panel to "OFF" mode.
Restart after the device stops working due to lack of fuel:
remove carbon from the burner;
pour fuel into the tank;
set the control panel to "OFF" mode;
feed fuel to the burner using the manual fuel feed function "TEST";
feed fuel until clean pellets appear at the beginning of the burner;
set the mode on the control panel to "ON"; after a few minutes the flame appears;
If there is no igniter, light the fire traditionally with lighter for barbecue;
switch on the air blower in "TEST";
after lighting up, set the control panel to "ON" mode.
Automatic start-up of the boiler after replacement of the overload clutch fuse:
remove carbon from the burner;
turn the worm clockwise and counterclockwise, then check if there is no "foreign matter" inside, e.g. a
stone or a rod; if there is, pull it out and replace the pin;
pour fuel into the tank;
set the "OFF" mode on the control panel;
feed fuel to the burner with the manual fuel feed function, "TEST" mode;
feed fuel until clean granules appear at the beginning of the burner;
set the mode on the control panel to "ON", after a few minutes the flame appears;
If there is no igniter, light the fire traditionally with lighter for barbecue;
switch on the air blower in "TEST;
after lighting, set the control panel to "ON" mode.
ATTENTION!
Remember to close the feeder lid tightly.
ATTENTION!
Do not stand in front of the boiler when opening the door as this can cause burns.
ATTENTION!
If the boiler is equipped with a lambda probe, it is advisable to use a flue gas analyser to
set its characteristics, when setting the blower power for subsequent boiler outputs.