METAL-FACH
Heating Technology
26
VST 112 valve
The emergency extinguishing device, protecting against ignition of fuel in the tank, can also be connected to the
water supply system and in case of exceeding the preset temperature, the extinguishing device opens the water
valve and operates independently from the electrical supply.
Thanks to a suitable construction of boilers of the SEG BIO series, the danger of fire entering the fuel tank is
small and is counteracted by a tight construction of the fuel feeder / protected by a limit switch.
ATTENTION!
The gas pressure in the expansion vessel should be checked and adjusted before using
the boiler. The expansion vessel should be checked once a year.
ATTENTION!
Install the safety valve at or near the heat source, e.g. on the system feed pipe, in an easily
accessible location.
ATTENTION!
The safety valve shall prevent the maximum operating pressure from being exceeded by
more than 10%.