METAL-FACH
Heating Technology
10
Boiler technical data
(User | Installer)
Parameters
S.I. Unit.
Boiler model
SEG BIO 15
SEG BIO 20
SEG BIO 30
Nominal heat output
[kw]
14
19
25
Boiler output range
[kw]
4,2-14
5,7-19
7,5-25
Heating surface
[m
2
]
2,1
2,54
2,85
Water volume
[L]
60
68
73
Maximum operating pressure
[bar]
3
3
3
Maximum operating temperature
[°C]
80
80
80
Test pressure
[bar]
4,5
4,5
4,5
Boiler class
[-]
5
5
5
Boiler efficiency
[%]
≤90
≤90
≤90
Fuel tank capacity
[L]
190
290
350
Fuel
[-]
Wood pellets of class C in accordance with pt. 5.3
(Table 7) of PN EN 303-5:2012 standard:
(diameter: 6 ± 1 mm; 8 ± 1mm, length 3.15 ≤ L ≤ 40,
moisture content ≤ 12%, ash content ≤ 0.5%, calorific
value >17 MJ / kg)
Electrical connection
[-]
5A; ~230V; 50Hz
Electric power consumption
[W]
300
300
300
Electric power consumption (momentary
at start-up)
[W]
1000
1000
1000
Setting range of temperature regulator
[°C]
60-80
(in 1°C steps)
Required chimney draught
[Pa]
20
23
23
Design flow resistance ΔT [10K]
[mbar]
5,47
8,79
12,33
Calculation flow resistance ΔT [20K]
[mbar]
1,19
2,19
3,80
Weight of boiler
[kg]
396
474
510
*Weight of /- 5kg.