TS790+ & TS900+ Installation Manual
System Installation
19
Using the DATAC / RS232 Printer
1. Plug the DCI/MPA on to the PRINTER plug
(JP1) on the main control panel PCB.
2. Plug the other end of the DCI/MPA into the
DATAC or RS232 printer.
3. In order for the printer to work correctly
ensure the printer is set to the following:
Baud rate = 4800
Parity =
None
Start bits = 1
Stop bits = 2
Data bits = 8
DTR
= Normal
4. When set-up correctly the system program
details and event log can be printed.
5. When finished unplug the MPA/DCI. If the
printer is left connected events will be
printed as and when they occur.
Figure 23. Printer Connections