Quick Reference Engineers Menus
Engineers Menu 2
key Options
Page
1
View Circuits
A = Scroll Next Circuit
C = Scroll Previous Circuit
40
2
Set System Time
Enter time e.g. 1400 for 2.00pm
40
3
Set System Date
Enter date e.g. 2804 for 28 April
40
4
Change Passcode (Engineers)
Enter new passcode
40
5
Chime Circuits
A = Scroll Next Circuit
B = Toggle Chime / Silent
C = Scroll Previous Circuit
41
6
Alter 24Hr Group
A = Scroll Next Circuit
B = Toggle Armed / Omitted
C = Scroll Previous Circuit
41
7
Print System Log
Enter Number of events and press ENT
41
8
Configure Wards
Enter Circuit Number then press
A = Ward A
B = Ward B
C = Ward C
41
9
View System Log
A = Scroll Backwards
B = Toggle Name / Circuit Text
C = Scroll Forwards
42
0
Reset User Code 1
Press ENT to Reset User 1 to 5678
44
A
Start Call Back
1 = Call Back No. 1
2 = Call Back No. 2
3 = Call Back No. 3
ENT to start Call Back
44
Engineers Menu 3
key Options
Page
1
Time Switches
A = Time Switch A
1 = On Time 1
B = Time Switch B
2 = On Time 2
C = Time Switch C 3 = On Time 3
4 = Off Time 1
7 = 1st operates on
5 = Off Time 2
8 = 2nd operates on
6 = Off Time 3
9 = 3rd operates on
0 = Manually Switch Output
46
2
Part Set Groups
Enter Group:
Select Wards:
A = Part Set Group A
O = Ward S
B = Part Set Group B
A = Ward A
C = Part Set Group C
B = Ward B
C = Ward C
47
3
Code Set Groups
Enter Group:
Select Wards:
A = Part Set Group A
O = Ward S
B = Part Set Group B
A = Ward A
C = Part Set Group C
B = Ward B
0 = Full Set Group
C = Ward C
47
4
Engineers Name
Use Keyboard to enter text
48
5
Part Set Text
Enter Group:
A = Part Set Group A
B = Part Set Group B
C = Part Set Group C
Use Keyboard to enter text
48
6
Circuit Text
A = Scroll Next Circuit
B = Edit Text
C = Scroll Previous Circuit
48
7
Custom Text Menu
1 = Reset Message 2 = Banner Message
3 = Location Text
4 =Printer Header
5 = Part Set Banner
48
8
XNode Outputs
Enter Node Output No. 0 - 9 then enter type
49
9
Built In Tests
1 = System Current
2 = System Voltage
3 = Circuit Resistance 4 = Digi Test
49
0
View Activity Count
50
A
Custom Output A
51
B
Custom Output B
51
C
Modem Options
1 = Call back No 1 4 = Modem password
2 = Call back No 2 5 = Modem Site No
3 = Call back No 3 6 = Program Digicom
0 = Reset Digicom
52
Содержание TS790+
Страница 1: ...TS790 TS900 Intruder Alarm Control Panels Installation and Programming Manual...
Страница 11: ...TS790 TS900 Installation Manual System Installation 7 Control Panel PCB Layout Figure 6 TS790 TS900 Main PCB...
Страница 57: ...TS790 TS900 Installation Manual Engineer s Menu 3 53 Program Digi Flowchart...
Страница 63: ...TS790 TS900 Installation Manual Appendices 59 Figure 27 Commercial Premises...