System Installation
TS790+ & TS900+ Installation Manual
18
Figure 20. DC54/DC58 Connections
Plug-on digi-Modem Installation
A plug-on digi-modem DC58M may be fitted
inside the control panel to allow remote
interrogation and programming via a personal
computer (PC). It will also function as a standard
digicom (if required). The unit should be fitted in
accordance with the installation instructions
supplied with it and connected to the control
panel plug DIGI-MODEM using the lead
provided with the DC58M. The NVM within the
digi-modem can either be programmed via
the control panel,
(see page 52).
or by using an
engineer’s keypad plugged into the digi-
modem. The modem data is also programmed
via the control panel.
Figure 21. DC58M Digi-modem Schematic
Output Modules Installation (CPA6.OM)
Output Modules (CPA6.OM) can be used to
provide a set of outputs to LEDs or relays to
indicate either circuit alarm activations or circuit
mimic activations. The first output module
connected to the system will indicate circuits 1
to 8, the next modules will indicate circuits 9 to
16 etc. Output modules are normally fitted
inside the equipment they are controlling and
may be positioned up to 100 metres away from
the main panel. The output module should be
used and connected in accordance with the
instructions provided with it.
Figure 22. Output Module Connections
Connecting a Printer
The TS790+/900+ supports two type of printers,
the CPA6 printer (no longer available) and any
standard RS232 printer. When using an RS232
printer a DCI/MPA printer adaptor will be
required. Menvier Security supply a DATAC
printer kit which consists of a portable RS232
printer, charger unit and DCI/MPA adaptor.
Using the CPA6 Printer
1. Plug the CPA6 printer directly on to the
PRINTER plug (JP1) on the main control panel
PCB.
✦
DO NOT plug the printer into JP2 by mistake.
If you do then you will damage the printer.
2. The printer will printout a header, when
finished the system program details and
event log can be printed.
3. When finished unplug the printer. If the
printer is left connected events will be
printed as and when they occur.
Содержание TS790+
Страница 1: ...TS790 TS900 Intruder Alarm Control Panels Installation and Programming Manual...
Страница 11: ...TS790 TS900 Installation Manual System Installation 7 Control Panel PCB Layout Figure 6 TS790 TS900 Main PCB...
Страница 57: ...TS790 TS900 Installation Manual Engineer s Menu 3 53 Program Digi Flowchart...
Страница 63: ...TS790 TS900 Installation Manual Appendices 59 Figure 27 Commercial Premises...