1. Program the Detection Circuit as a “Key
Switch” and set the attributes as “F * * * |* A
* *”. The “F” attribute indicates that the “Full
Set Group” is selected when the keyswitch is
switched from “Healthy” to “Active”. The “A”
attribute indicates that “Code Set Group A” is
selected when the keyswitch is switched
from “Healthy” to “Shorted”.
2. Program the code set groups so that the
correct combination of wards are set and
unset. In this example the code set groups
are set as follows:
Full Set Group: [SABC]
Code Set Group A: [ AB ]
3. Program panel output 2 as “General Fault”
(044), this will provide a visual indication that
one or more circuits are in error when setting
the system.
Time Switch Application Example
This application example shows how to use
“Time Switch A” and the “Key Point” circuit to set
and unset the system. The time switch will be
programmed so that panel is automatically set
at 18:00 and unset at 08:00 from Monday to
Friday, and will then remain set over the
weekend.
Figure 29. Time Switch Wiring
1. Program the Detection Circuit as a “Key
Point” and set the attributes as “F * * * |* * *
*”. The “F” attribute indicates that the “Full Set
Group” is selected when the circuit changes
from “Healthy” to “Active”.
See “Program
Circuits”, on page 28).
2. Program the code set groups so that all
wards are set and unset for the “Full Set
Group”
(see “Code set Groups”, on page
47):
Full Set Group: [SABC]
3. Program Panel Output 1 as “Time Switch A”
(040), this is used to switch the “key Point”
circuit from “Healthy” to “Active”.
See “Panel
Outputs”, on page 25.
4. Program “Time Switch A” as follows,
see
“Time Switches”, on page 46.
:
Timer 1
Timer 2
Timer 3
On Time
18:00
00:00
00:00
Off Time
08:00
00:00
00:00
Mon
4
Tue
4
Wed
4
Thu
4
Fri
4
Sat
Sun
Alarm Abort & Confirmation
Both the TS790+ and TS900+ support “Alarm
Abort” and “Sequential Confirmation”. The alarm
abort can be achieved by either sending an
abort signal on a dedicated channel (normally
channel 7) or by restoring the alarm channel.
Alarm Abort Operation
When the alarm is triggered the system transmits
a Channel 3 (Alarm) to the central station. If the
system is unset within the “Abort Delay” period
the abort output is triggered and Channel 7
(Abort) is transmitted to the central station.
Sequential Confirmation Operation
When the first alarm is triggered, the system
transmits Channel 3 (Alarm) to the central
station. If a different zone is activated the
system transmits Channel 7 (Confirmed Alarm).
Содержание TS790+
Страница 1: ...TS790 TS900 Intruder Alarm Control Panels Installation and Programming Manual...
Страница 11: ...TS790 TS900 Installation Manual System Installation 7 Control Panel PCB Layout Figure 6 TS790 TS900 Main PCB...
Страница 57: ...TS790 TS900 Installation Manual Engineer s Menu 3 53 Program Digi Flowchart...
Страница 63: ...TS790 TS900 Installation Manual Appendices 59 Figure 27 Commercial Premises...