TS790+ & TS900+ Installation Manual
Appendices
55
Appendices
Contact ID Extended Reporting
Contact ID extended reporting is a new format
which when used with the DC58 or DC58M can
be used to report circuit ID data, user ID etc. In
order to used this format the DC58/DC58M must
be plugged on to the control panel and must
also be programmed to report “Extended
Format”
(refer to the instructions supplied with
the DC58/DC58M).
The central station alarm
receiver must also be capable of receiving
“Contact ID extended Format”.
Contact ID Reporting takes the following format:
CCCC Q EEE GG ZZZ where:
CCCC
Customer account number.
Q
Event qualifier, where E = new event (1) and R
= restore (3).
EEE
Event code (see table below).
GG
Always 00.
ZZZ
Circuit/Contact ID number reporting the alarm
(001-056), or user number (001-031) for
open/close reports. System status messages
(Mains Fail, Walk Test, etc.) contain zeros in the
ZZZ location.
Code Description
110
Fire alarm
120
Panic (PA Code) alarm
121
Duress alarm
122
Silent PA alarm
123
Audible PA alarm
130
*Intruder alarm
134
Entry alarm
135
24 Hour alarm
137
Equipment tamper alarm
139
Confirmed alarm
150
Auxiliary alarm
Code Description
301
Mains failure
302
Low system battery
305
System reset (on-site or factory)
309
Battery test failure
382
Node or Remote removed
401
Open / Close by user
406
Alarm cancelled
409
Open / Close by keyswitch
411
Call-back requested (Lineload)
412
Successful download access
413
Unsuccessful download access
465
Restore PA
570
Circuits omitted
572
24 Hour circuits omitted
573
Cct "Actively" omitted
627
Engineer program mode selected
628
Engineer program mode cancelled
Contact ID Event Codes
*Becomes CCT Tamper if Engineer menu 1.9
option 30 is set to "Tamper is Burg".
Resetting the Engineers passcode
If the installation engineer has inadvertently
changed the engineers passcode or the
passcode has been forgotten, the passcode
can be reset back to 1234 without losing any
other programmed data. This procedure can
only be used providing a user passcode is
available:
1. Ensure that the system is unset and a user
passcode is available.
2. Remove the cover from the control panel,
this will cause a "Panel Lid tamper" alarm.
3. Ask the user to enter their passcode to
silence the alarm.
4. Place the blade of a small screwdriver
between the pins labelled "FACTORY RESET".
A multi-tone sound indicates the engineers
passcode has been reset.
5. Replace the control panel cover. At the
remote keypad enter 1234. The display will
show “Engineers Menu 1". To change the
engineer’s passcode
see ”Change
Passcode” on page 40.
Содержание TS790+
Страница 1: ...TS790 TS900 Intruder Alarm Control Panels Installation and Programming Manual...
Страница 11: ...TS790 TS900 Installation Manual System Installation 7 Control Panel PCB Layout Figure 6 TS790 TS900 Main PCB...
Страница 57: ...TS790 TS900 Installation Manual Engineer s Menu 3 53 Program Digi Flowchart...
Страница 63: ...TS790 TS900 Installation Manual Appendices 59 Figure 27 Commercial Premises...