33
7.3
Measurement Screen
Elements of the
measurement screen
The actual measurement screen is continuously updated during the measurement and
offers the following information and buttons:
Element Description
Current measured value.
Using the buttons on the right, the following measurement values can be
switched between:
Phase
Phase of the connected conductor according to the
assignment defined under
PhaseID
(see section 7.1)
Angle
Phase shift with respect to the reference phase according to
the
Display Range
defined under device settings (see
section 7.1)
List
List of the last seven recorded phase angles, updated every
second
Pointer
Vector diagram displaying the reference and measurement
voltage vectors
Phase shift with respect to the reference phase according to the
Display
Range
defined under device settings (see section 7.1).
Name of the currently selected measurement profile and the phase
correction angle stored in this profile.
The measurement profile can be changed during the measurement using
this button, thus avoiding having to reconnect to the base station. This
works only if the function
Profile change
is activated under device
settings (see section 7.1).
The measurement can be stopped at any time by pressing the
Stop
touchpad.
Battery status display of the connected HV sensor. This symbol is shown
only during a measurement with the HV sensor.
Daten
U
X
U
V
Phase
Angle
-0.1°
GSM
GPS
PVS
List
HVS
Pointer
L1
0
Phase corr.: -2.8°; LV1;
Stop
Содержание PVS 100i