ON-BOARD DIAGNOSTIC
07-02–3
07-02
ON-BOARD DIAGNOSTIC FUNCTION
id070200100300
Malfunction Detection Function
!
Detects errors in the input and output signals. (The ignition switch is at the ON position or the engine is
running.)
!
If a malfunction is detected, a DTC is output to the information display through the malfunction display function.
At the same time, malfunction detection results are sent to the fail-safe and memory functions.
Fail-safe Function
!
If a malfunction is detected by the malfunction detection function and a malfunction is determined, the following
controls are performed to prevent mis-operation of the full-auto air conditioner and malfunction of output parts.
Fail-safe Function Table
Memory Function
!
Stores the signal determined to be malfunctioning by the malfunction detection function, and the memory
cannot be cleared even if the ignition switch is at the LOCK position or the malfunction has been repaired.
!
To clear stored malfunction information, press the climate control unit AUTO switch and the REC/FRESH switch
simultaneously during past malfunction display mode.
Malfunction
determination part
When malfunction is determined at IG SW
ON
When IG SW is turned to ON during
malfunction
Passenger compartment
temperature sensor
Passenger compartment temperature sensor
input value is set at
25
$
C {77
$
F}
.
"
Ambient temperature
sensor
Ambient temperature sensor input value is set
at the value just before the malfunction.
"
Evaporator temperature
sensor
Evaporator temperature sensor input value is
set at
0
$
C {32
$
F}
.
"
Solar radiation sensor
Solar radiation sensor set value is set at
0 W/
m
2
.
"
ECT sensor
ECT sensor input value is set at
80
$
C {176
$
F}
.
"
Air mix actuator
(Potentiometer)
Stops the air mix actuator drive signal at the
point a malfunction is determined.
However, MAX COLD when the manually set
temperatures is at
18.0
, and MAX HOT when
the manually set temperature is
32.0
.
"
Airflow mode actuator
(Potentiometer)
Stops the mode actuator drive signal at the
point a malfunction is determined.
However, for manual operation with the airflow
mode selector switch, only vent mode is
operable.
Defroster switch operation is operable
"
Air mix actuator
(Motor lock)
Stops the air mix actuator drive signal at the
point a malfunction is determined. Then a drive
signal is output to the air mix actuator for
approx. every 5 min
and malfunction
determination is performed.
After the IG SW is at ON, regular output of the
air mix actuator drive signal recommences.
Then a drive signal is output to the air mix
actuator
approx. every 5 min
and malfunction
determination is performed.
Airflow mode actuator
(Motor lock)
Stops mode actuator drive signal at the point a
malfunction is determined. Then a drive signal
is output to the mode actuator
approx. every 5
min
and malfunction determination is
performed.
After the IG SW is at ON, regular output of the
mode actuator drive signal recommences.
Then a drive signal is output to the mode
actuator
approx. every 5 min
and malfunction
determination is performed.
Содержание 2009 RX-8
Страница 8: ......
Страница 14: ......
Страница 36: ......
Страница 52: ......
Страница 66: ......
Страница 70: ......
Страница 76: ......
Страница 106: ......
Страница 116: ......
Страница 124: ......
Страница 128: ......
Страница 142: ......
Страница 156: ......
Страница 175: ......
Страница 183: ......
Страница 201: ......
Страница 203: ......
Страница 213: ......
Страница 285: ......