CONTROL SYSTEM [FULL-AUTO AIR CONDITIONER]
07-40–12
Correction
Mild start correction
x
Controls blower motor applied voltage for a maximum of
17 s
when the blower motor is started in summer to
prevent discomfort caused by a high volume of hot air blown from the blow-off opening. However, the mild start
correction is not performed when the airflow is in a mode other than VENT, the A/C mode is off, or the target
temperature is high.
Warm-up correction
x
Controls blower motor applied voltage in accordance with the increase in engine coolant temperature to prevent
discomfort caused by a high volume of cold air blown from the blow-off opening. However, the warm-up
correction is not performed in a mode other than HEAT or HEAT/DEF, or when the target temperature is low.
MAX HOT and MAX COLD correction
x
If the set temperature is at
32.0
or
18.0
, the
blower motor applied voltage is fixed at HI.
However, during the warm-up correction, the MAX
HOT correction is not performed.
Defroster correction
x
When the defroster switch is turned on, air
volume is increased by adding blower motor
applied voltage (
2 V
) to improve defrosting.
Burn prevention function at start
x
If the blower motor is started from a stopped
condition with a blower motor applied voltage at
4.0 V or more
, the blower motor applied voltage
is fixed at
4.0 V
for
2 s
to prevent blower motor
burning due to excess electrical current.
Airflow Volume Manual Control
x
The blower motor applied voltage (air volume) can be switched between seven steps by operation of the fan
switch.
End Of Sie
NG: AIRFLOW MODE CONTROL
AIRFLOW MODE CONTROL OUTLINE [FULL-AUTO AIR CONDITIONER]
id0740a1102700
Features
x
The airflow mode control includes the airflow mode automatic and manual controls, and the A/C amplifier
controls the airflow mode actuator to switch the blower mode.
End Of Sie
㧒
S
㧓
7
10
17
HI
LO
BLO
WER MO
TOR APPLIED
V
OL
TA
GE
EVAPORATOR TEMPERATURE 4
°
C {39
°
F} OR LESS
EVAPORATOR TEMPERATURE 10
°
C {50
°
F} OR MORE
ar8uun00000063
40 {104}
68 {154}
°
C {
°
F}
OFF
LO
HI
BLO
WER MO
TOR
APPLIED
V
OL
TA
GE
ENGINE COOLANT TEMPERATURE
ar8uun00000064
Fan switch
Blower motor applied voltage
1st speed
3.4 V
2nd speed
5.0 V
3rd speed
6.6 V
4th speed
8.2 V
5th speed
9.8 V
6th speed
11.4 V
7th speed
B+
Содержание 2009 RX-8
Страница 8: ......
Страница 14: ......
Страница 36: ......
Страница 52: ......
Страница 66: ......
Страница 70: ......
Страница 76: ......
Страница 106: ......
Страница 116: ......
Страница 124: ......
Страница 128: ......
Страница 142: ......
Страница 156: ......
Страница 175: ......
Страница 183: ......
Страница 201: ......
Страница 203: ......
Страница 213: ......
Страница 285: ......