CONTROL SYSTEM [FULL-AUTO AIR CONDITIONER]
07-40–10
Correction
Air mix actuator stop position correction
x
The A/C amplifier maintains the actuator at the stop position calculated based on the position signal from the
potentiometer inside the air mix actuator.
MAX HOT and MAX COLD correction
x
When the set temperature is at
32.0
, the air mix actuator becomes MAX HOT, when it is at
18.0
, it becomes
MAX COLD.
End Of Sie
NG: AIRFLOW VOLUME CONTROL
AIRFLOW VOLUME CONTROL OUTLINE [FULL-AUTO AIR CONDITIONER]
id0740a1102400
Features
x
The airflow volume control includes the airflow volume automatic and manual controls, and the A/C amplifier
controls the power transistor to adjust the blower air volume.
End Of Sie
AIRFLOW VOLUME CONTROL SYSTEM DIAGRAM [FULL-AUTO AIR CONDITIONER]
id0740a1102500
End Of Sie
AIRFLOW VOLUME CONTROL OPERATION [FULL-AUTO AIR CONDITIONER]
id0740a1102600
Order of Priority for Controls
1. Blower motor correction at start
2. Airflow volume manual control
3. MAX HOT and MAX COLD correction
4. Airflow volume automatic control
-3
3
-4
4
/
(%)
A/C AMPLIFIER
POSITION
SIGNAL
AIR MIX ACTUATOR
AIR MIX A
CTU
AT
OR
OPERATING
STOPPED
TARGET OPENING ANGLE — ACTUAL OPENING ANGLE
ar8uun00000060
FAN SWITCH
SET
TEMPERATURE
EVAPORATOR
TEMPERATURE
AIRFLOW
MODE
AMBIENT
TEMPERATURE
CABIN
TEMPERATURE
SOLAR RADIATION
AMOUNT
ENGINE
COOLANT
TEMPERATURE
ECT
SENSOR
SIGNAL
A/C
AMPLIFIER
OUTPUT
FEEDBACK
POWER
TRANSISTOR
BLOWER
MOTOR
OPERATION
AIRFLOW
VOLUME
CHANGE
ar8uun00000325
Содержание 2009 RX-8
Страница 8: ......
Страница 14: ......
Страница 36: ......
Страница 52: ......
Страница 66: ......
Страница 70: ......
Страница 76: ......
Страница 106: ......
Страница 116: ......
Страница 124: ......
Страница 128: ......
Страница 142: ......
Страница 156: ......
Страница 175: ......
Страница 183: ......
Страница 201: ......
Страница 203: ......
Страница 213: ......
Страница 285: ......