ON-BOARD DIAGNOSTIC [13B-MSP]
01-02–10
Sending Intermittent Monitoring System Test Results
x
The items supported by the sending intermittent monitoring system are shown below.
*1
: California emission regulation applicable model
End Of Sie
DTC DETECTION LOGIC AND CONDITIONS [13B-MSP]
id0102g1100300
x
The detection condition of the following DTC has been changed from 2008MY.
B1342 PCM malfunction
x
Malfunction in the PCM internal circuit.
P0030 A/F sensor heater control circuit problem
x
The PCM monitors the A/F sensor impedance when under the A/F sensor heater control for
190 s
. If the
impedance is more than
44 ohms
while PCM turns A/F sensor heater on, the PCM determines that there is a
A/F sensor heater control circuit problem.
P0031 A/F sensor heater control circuit low input
x
The input voltage to the A/F sensor heater drive terminal in the PCM is at the set value or less for
1 s or more
even though the A/F sensor heater is duty-controlled at
under 90 %
by the PCM.
P0032 A/F sensor heater control circuit high input
x
The input voltage to the A/F sensor heater drive terminal in the PCM is at the set value or more for
1 s or more
even though the A/F sensor heater is duty-controlled at
10 % or more
by the PCM.
P0037 HO2S heater control circuit low input
x
The input voltage to the HO2S heater drive terminal in the PCM is at the set value or less for
0.5 s or more
even though the HO2S heater is duty-controlled at
under 90 %
by the PCM.
P0038 HO2S heater control circuit high input
x
The input voltage to the HO2S heater drive terminal in the PCM is at the set value or more for
0.5 s or more
even though the HO2S heater is duty-controlled at
10% or more
by the PCM.
P0103 MAF sensor circuit high input
x
The PCM monitors the input voltage from the MAF sensor when the engine is running. If the input voltage is
more than 5.0 V
, the PCM determines that the MAF sensor circuit input voltage is high.
P0107 BARO sensor circuit low input
x
The PCM monitors the input voltage from the BARO sensor when the engine is running. If the input voltage is
less than 2.09 V
, the PCM determines that the BARO sensor circuit input voltage is low.
OBD monitor ID
Test ID
Description
Related
system
Scaling
ID
Unit
2009MY
2008MY
01
m
80
Response lean to rich
A/F sensor
20
Ratio
01
m
81
Response rich to lean
20
Ratio
01
m
82
Response lean to rich delayed
10
Time
01
m
83
Response rich to lean delayed
10
Time
02
m
03
Low sensor voltage for switch time calculation
HO2S
0A
Voltage
02
m
04
High sensor voltage for switch time calculation
0A
Voltage
02
m
05
Rich to lean sensor switching time
10
Time
02
N/A
80
Response timeout
10
Time
21
m
80
Rear to front switching ratio
Catalyst
20
Ratio
3A
m
80
Large leak check
EVAP system
0D
Current
3B
m
80
Small leak check
0D
Current
3C*
1
m
80
Very small leak check
05
Raw
value
3D
m
80
Purge flow monitor
0D
Current
71
m
80
Secondary air functional check
AIR system
10
Time
71
m
81
Secondary air flow rate check
86
Raw
value
A2
m
0B
Exponentially weighted moving average misfire counts
for last 10 driving cycles (front rotor)
Misfire
24
Counts
A2
m
0C
Misfire counts for last/current driving cycles (front
rotor)
24
Counts
A3
m
0B
Exponentially weighted moving average misfire counts
for last 10 driving cycles (rear rotor)
24
Counts
A3
m
0C
Misfire counts for last/current driving cycles (rear
rotor)
24
Counts
Содержание 2009 RX-8
Страница 8: ......
Страница 14: ......
Страница 36: ......
Страница 52: ......
Страница 66: ......
Страница 70: ......
Страница 76: ......
Страница 106: ......
Страница 116: ......
Страница 124: ......
Страница 128: ......
Страница 142: ......
Страница 156: ......
Страница 175: ......
Страница 183: ......
Страница 201: ......
Страница 203: ......
Страница 213: ......
Страница 285: ......