58
59
MAXDATA SN 40 M1 – User Guide
Managing Your Storage System
58
59
MAXDATA SN 40 M1 – User Guide
Managing Your Storage System
Responding to RAID Failure
When disk removal/failure causes the entire RAID to fail, the “Disk Change Notification” page appears
when you access the Manager or refresh the browser window:
Figure 28. RAID Failure
Take the appropriate action:
To do this
Do this
Scan the storage system again and
update the information on the page
Click “Scan”.
Re-install the same disk
Click “Shut Down”.
After the storage system shuts down, re-install the same disk
and then restart the system.
NOTE
If you removed multiple disks, be sure to re-install them in
the opposite order than you removed them.
Reconfigure the storage system using
the available disks
Click “Reconfigure Disks” and complete the system setup
pages.
Caution
Reconfiguring the storage system deletes all user information and all data on all the disks.