7.02
Maintenance
TI008G0001
Regular Checks
WARNING !!!
After the first 50 hours of operation and every 6 months or 1000 hours:
-
tighten nuts and screws fixing the cables in the command and control electrical
board and in the terminal board of electrical motors.
Within the first 300 hours of operation:
- clean the oil return valves (Page 7.05).
Weekly (or every 50 hours)
- Check the oil level
-
Check and Clean the condensate drain sole-
noid valve filter (with optional kit).
Monthly (or every 200 hours)
-
Clean the intake filter.
-
Clean the oil cooler and the compressed air
after cooler.
- Clean the pre-filter of the suction grids
Every three months (or every 500 hours)
- Clean the oil return valves
Every 6 months (or every 1.000 hours)
-
Replace the intake filter
-
Tighten nuts and screws fixing the wires inside
the start and control panel and inside the mo-
tor terminal board.
- Grease the motor bearings
Yearly (or every 2.000 hours)
- Replace the oil return valves
Oil change
Rotoroil 8000 F2
:
- every 12 months or 5.000 hours
Rotoroil 8000 F4
:
- every 12 months or 5.000 hours
Rotoroil 8000 FG
:
- every 12 months or 1.000 hours
Replace the oil filter at every oil change.
WARNING !!!
In dusty environments and/or at high temperatures maintenance operations should be car-
ried out more frequently.
The manufacturing date is quoted on rubber hoses.
Their operating life is 3 years, after which they should be replaced.
WARNING !!!
Scheduled maintenance agreements are available, to help the user keeping the machines
at best operating and efficiency conditions.
Please apply to
Ing. ENEA MATTEI S.p.A. / M.T.A.
for further details.
WARNING !!!
For compressors equipped with INVERTER, before performing any maintenance job,
wait at least 5 minutes after you have disconnected the electricity supply.
!
098
102
101
!
098
!
098
!
098