Trouble Shooting Check List

Problem

Possible Causes

Corrective Action

Compressor will not

run

No power is coming

from the 12 volt

source

Make sure

compressor switch

is on

Power switch is in

off position

Make sure

compressor switch

is on

Blown fuse

Disconnect

compressor from

power source,

replace fuse 

- 50 amps

Motor overheated

Let compressor

cool off for about

30 minutes so

thermal overload

switch will reset

Thermal overload

protector cuts out

repeatedly

Lack of proper

ventilation/ambient

temperature is too

high

Move compressor

to well ventilated

area or area with

lower ambient

temperature

Compressor valves

failed

Replace

compressor

Excessive knocking

or rattling

Worn bearing on

eccentric or motor

shaft

Replace

compressor

Cylinder or piston

ring is worn

Replace

compressor

Compressor air flow

lower than normal

or cannot pump to

higher pressures

Worn piston ring or

inlet valves

Replace

compressor

Britpart

, The Grove, Craven Arms, Shropshire, SY7 8DA

www.britpart.com

Specifications

Part number

DA2392

Motor voltage

12 volt

Motor type

Permanent magnetic

Max working pressure

150psi

Max flow rate @ 0psi (13.8v)

150 litres

Continuous use @ 22ºC & 40psi 30 minutes
Max restart pressure

150psi

Max current consumption

45 amps

Built-in fuse

50 amps

Auto reset thermal protection

Yes

Dimensions

280 x 140 x 200mm

Net weight

4.6kg