TI008G0001
Decommissioning and dismantling
Only authorised staff is allowed to decommission and remove the machine.
Before setting the machine out of operation it is necessary to disconnect the mains isolator and block
it in the open position.
Discharge oils and fluids, remove all moving parts.
Disconnect the mains isolator cable, by cutting out the power wires and then the earth wire.
Disconnect the power supply cable from the machine main switch and remove it.
Disconnect the machine pneumatic equipment from the air distribution system.
Remove the machine from the working area following the instructions given in this manual. Before lifting
it, verify the correct use of lifting devices and use only suitable equipment.
Waste disposal should be performed in compliance with the laws in force in the country where the ma-
chine is installed.
❑
Installation, setting up and use of compressor should be carried out in compliance with the standards
and the rules in force concerning safety at work.
❑
The owner of the machine is responsible for its good maintenance, an essential condition to ensure
safe operation.
Those machine parts that due to improper use or wear do not ensure safe operation should be
quickly replaced.
❑
Only trained, authorised and skilled staff should perform the installation, use, maintenance and
repairs.
❑
In case of difference between the instructions given in this manual and those foreseen by current
laws concerning safety, it is recommended to apply the more restrictive ones.
Maintenance and repair
Only authorised personnel should carry out maintenance, troubleshooting and repairs.
Any maintenance and repair in progress should be signalled by a specific sign, stating the maintenance
condition and placed on the control panel until completion of the job, even if temporarily interrupted.
All operations for installation, maintenance or replacement of components on the machine or on the
control unit should be performed with switched off system.
Therefore, the main switch should be on OFF (OPEN) position and blocked with the safety lock to prevent
any movement to the ON position.
For compressors equipped with INVERTER, before performing any maintenance job, wait at
least
5 minutes after you have disconnected the electricity supply.
Before acting, people in charge of maintenance should first check following conditions:
• that any receiver under pressure has been exhausted.
Before intervening on pneumatic or lubricating systems and specifically on pipes, receivers, hoses and
other components under pressure, the staff in charge of maintenance should reduce the internal pres-
sure of the plant down to the ambient pressure value.
Faulty components must be replaced with others having the same code.
If during troubleshooting it is necessary to carry out jobs with the control unit and the machine live, all
precautions should be taken, as required by the safety standards to operate under dangerous voltages
and with moving parts.
At the end of the maintenance and troubleshooting jobs, all disconnected safety devices should be
reset.
Maintenance, repair and troubleshooting should be ended by the checking of the machine operation
and of all its safety devices.