5.01
Safety Devices
TI008G0001
EMERGENCY - STOP button
The machine stops immediately when the button
is pressed.
This button is to be used also in an
emergency situation.
Frequent stops of the compressor by
means of this button
may damage its
operation
.
WARNING
Please refer to the Manual of "
MA-
ESTRO
XS
" Control attached to this
Manual for detailed, description of keys,
programming, and all of its functions.
Safety Valve
A “SAFETY VALVE ”protects the compressor in case
of air overpressure inside the chamber,while limiting
the value to its own setting limit.
The safety valve is set at 12 bar for L and H version
of compressors and 15 bar for HH versions.
Operating pressure check
For compressors of the AC 6000 series the operating
pressure is checked by MAESTRO
XS
.
The maximum operating pressure is set during
final inspection at its optimal value and DOES NOT
require any further adjustments.
Note
Compressor operation depends on
the set values; it is suggested to ask
for modification of settings only in case
of real need and with knowledge.
Only skilled personnel should make
the setting.
Setting Maximum Pressures
Version
L
H
HH
Maximum pressure
8 bar 10 bar 13 bar
☞
!
098
918
103
921a