2.02
General Information - Safety
TI008G0001
After having carefully considered all possible risks concerning the use and maintenance of the machine,
all measures have been adopted to eliminate risks and limit dangers to exposed people.
Although the machine is equipped with safety devices, the following residual risks remain, which can be
eliminated or reduced by the relevant precaution:
• Risk of bruises, tearing, cuts during the handling of tools and/or elements.
• Risk of bruises during machine intervention.
Operation
❑
The operator should use the personal protection devices.
❑
Use the compressor only for the kind of application for which it is designed (air compression for
industrial use).
❑
Before starting, ensure that compressor is filled with oil.
❑
Please refer to Section 8 of this manual for the oil type to be used.
❑
Never operate the compressor if there is a possibility of inhaling smoke or toxic or flammable va-
pours.
❑
Never operate the compressor at higher pressures than those indicated in the id plate.
The air delivered by the compressor must not be used for breathing, although it is filtered
and purified from oil.
❑
If hoses are used to distribute the air, ensure they are properly sized and suitable for the operating
pressure, and not damaged or worn.
Please remember that rubber hoses should be replaced at regular intervals.
❑
Never remove the oil filler plug when the machine is running or there is still pressure inside the
compressor: there would be hot oil leak.
❑
Although it has an acceptable sound pressure level, the machine can produce a much higher noise
if the room is narrow and reverberating. Please note that the continuous presence of an operator
is unnecessary.
For safey against noise, in compliance with local laws in force, and if necessary, place specific warn-
ing signs near the machine and equip personnel with suitable protections.
Installation
Besides fulfilment of rules and regulations issued by the authorities, it is recommended to con-
sider the following:
❑
The compressor will perform most efficiently if installed in a suitable, well ventilated area and far
from heat sources.
❑
Should any duct be installed for the suction and cooling of air, always use the data and recommen-
dations given in Section 4 and preferably obtain expert advice during the design stage.
❑
In case of outdoor installation (not suggested for very cold climates) it is necessary to place the
machine under a roof or covering, to protect it against weather.
❑
Be careful that no foreign materials clogg the radiator and cause rises of the operating tempera-
ture.
❑
The intake air must be clean and free from flammable vapours, which could cause fires or explo-
sions.
❑
As the machine is air cooled, adequate ventilation must be ensured to prevent it from overheating
and thus avoiding the recirculation of the expelled hot air.
❑
Control and safety devices should never be tampered with.
❑
If one or more compressors are installed on a single pneumatic line, it is essential that each unit is
equipped with a detect valve.
❑
Electrical connection should be conforming to current regulations. The machines should be earth
connected and protected by a magneto-thermal switch against possible short circuits.
❑
It is essential to install a mains isolating switch upstream of the compressor.