11 When You Were In Trouble
80
HARS series
11 When You Were In Trouble
"Something wrong?" If you think a failure has occurred, first turn off the unit and check the following items.
They are not always a failure in the following cases, check the unit once again before requesting our services.
Problem
Items to check
The output does not meet
the preset value.
☐
Is the input voltage within the specifications? Is the wiring correct?
(Refer to 3-1)
☐
Is the setting of the external switch correct? (Refer to 6-2.)
≪
Local control
≫
☐
Has the CV or CC setting not been set to the lowest possible value?
(Refer to 5-1-3.)
☐
Is the overvoltage protection setting correct? (Refer to 4-5.)
☐
Is the overcurrent protection setting correct? (Refer to 4-5.)
☐
Isn't the LOCK function activating? (Refer to 5-1-5.)
<Remote control>
☐
Is the ON/OFF switch turned ON? (Refer to 5-1-4.)
☐
Is the external switch setting correct? (Refer to 6-2.)
☐
Isn't it in analog remote? (Refer to 6-4.)
☐
Isn't it in digital remote? (Refer to 7.)
Fuse blows.
Breaker trips.
☐
Have you replaced the original screws of the housing with different ones?
(Refer to 2-6-3.)
(The screws may have reached the inside of the product.)
☐
Is the breaker's base capacity sufficient?
The output voltage
fluctuates or out of control.
☐
Isn't it in CC mode? (Refer to 4-1-3.)
☐
Isn't the LOCK function activating? (Refer to 5-1-5.)
Reset to factory default:
If you lose how to set or are unable to use the unit normally during use, you can restore factory default.
* If nothing meets the above case, or if the problem is not solved after checking, please contact our sales
office where you purchased the product.
System settings
Home screen
Menu
System reset
Reset to factory default.
Содержание HARS Series
Страница 1: ...Instruction Manual F RA 001 3R3 MODEL HARS series B N 277 9 002 277 9 002 Rev 0 1 ...
Страница 10: ......
Страница 19: ...2 Before Using This Product 9 HARS series 2 6 3 Dimensions a Models 500W 1kW 60kV or lower ...
Страница 20: ...2 Before Using This Product 10 HARS series b Models 500W 1kW 100kV 120kV ...
Страница 21: ...2 Before Using This Product 11 HARS series c Models 2kW 3kW 60kV or lower ...
Страница 22: ...2 Before Using This Product 12 HARS series d Models 2kW 3kW 100kV 120kV ...
Страница 92: ......