5 Operation on the Main Unit
43
HARS series
In the pulse sequence setting screen, touch the pulse sequence ON/OFF button to set it to Enable.
Set the output ON time (ON time). (0.1s to 99h59m59.9s)
Sets the output OFF time (OFF time). (0.0s to 99h59m59.9s)
Set the number of repetitions (Repeat). (0 to 9999) If 0 is set, ON/OFF is infinitely repeated. (0 to 9999)
To use the multiset memory together, set the multiset function to Enable on the multiset setting screen.
Set the output ON time (A-ON time/B-ON time/C-ON time) for each of the multiset memory A, B, and C.
(0.0s to 99h59m59.9s)
When multi-set memory is enabled, the output ON time (ON time) is not used.
To change each setting value, touch each item on the touch panel display.
Example: Multiset memory is not used.
OUTPUT
ON
When the repeat count is 0,
ON/OFF is infinitely repeated until OUTPUT OFF.
ON time
OFF time
1 cycle
If the repeat count is1, end here.
Example) Multiset memory is used together.
OUTPUT
ON
When the repeat count is 2, ON/OFF is
repeated twice, and automatically
stopped.
A-ON time
B-ON time
1 cycle
Stop
Pulse
sequence
C-ON tim
e
OFF time
Memory a, b and c
*Output for multiset memory ON time
The word "Sequence" will blink in the upper left corner of the home screen while the pulse sequence is
performed.
Home screen
Содержание HARS Series
Страница 1: ...Instruction Manual F RA 001 3R3 MODEL HARS series B N 277 9 002 277 9 002 Rev 0 1 ...
Страница 10: ......
Страница 19: ...2 Before Using This Product 9 HARS series 2 6 3 Dimensions a Models 500W 1kW 60kV or lower ...
Страница 20: ...2 Before Using This Product 10 HARS series b Models 500W 1kW 100kV 120kV ...
Страница 21: ...2 Before Using This Product 11 HARS series c Models 2kW 3kW 60kV or lower ...
Страница 22: ...2 Before Using This Product 12 HARS series d Models 2kW 3kW 100kV 120kV ...
Страница 92: ......