7 Operating with Digital Control
56
HARS series
7-3 SCPI Command List
SCPI Command List
Command
Function
Unit
*IDN?
Gets company name, model name, serial No.,
version info.
-
*RST
Resets parameters.
-
SYSTem
:LOCal
Sets local mode.
-
:REMote
Sets remote mode.
-
:MODe?
Gets the status
-
INSTruments
-
[:NSELect]
<n | ALL>
Specify UNIT number responded to SCPI
command
-
MEASure
[:SCALar]:VOLTage[:DC]?
Gets the output voltage value.
-
[:SCALar]:CURRent[:DC]?
Gets the output current value.
-
[SOURce:]
VOLTage[:LEVel][:IMMediate][:AMPLitude]
<n | MINimum | MAXimum>
Sets the voltage value.
Volts
:PROTection[:LEVel] <n | MINimum | MAXimum >
Sets OVP value.
Volts
:LIMit[:UPPer][:IMMediate][:AMPLitude]
<n | MINimum | MAXimum>
Sets Limit voltage value.
Volts
CURRent[:LEVel][:IMMediate][:AMPLitude]
<n | MINimum | MAXimum>
Sets the current value.
Amps
:PROTection[:LEVel] <n | MINimum | MAXimum >
Sets OCP value.
Amps
:LIMit[:UPPer][:IMMediate][:AMPLitude]
<n | MINimum | MAXimum>
Sets Limit current value.
Amps
OUTPut
[:STATe] <OFF | ON | 0 | 1>
Change the output status.
-
* About [ ]:
Optional
* About <>:
Sets parameters.
Set the desired value for n, and the maximum/minimum value for MAX/MIN.
“ON” or “1” sets "ON" and “OFF” or “0” sets "OFF".
* Uppercase letters must be stated; lowercase letters are optional.
(e.g. SYSTEM:LOCAL is synonymous with SYST:LOC.)
Содержание HARS Series
Страница 1: ...Instruction Manual F RA 001 3R3 MODEL HARS series B N 277 9 002 277 9 002 Rev 0 1 ...
Страница 10: ......
Страница 19: ...2 Before Using This Product 9 HARS series 2 6 3 Dimensions a Models 500W 1kW 60kV or lower ...
Страница 20: ...2 Before Using This Product 10 HARS series b Models 500W 1kW 100kV 120kV ...
Страница 21: ...2 Before Using This Product 11 HARS series c Models 2kW 3kW 60kV or lower ...
Страница 22: ...2 Before Using This Product 12 HARS series d Models 2kW 3kW 100kV 120kV ...
Страница 92: ......