7 Operating with Digital Control
68
HARS series
IGET Command
Monitors the output current.
Range
0 to Rated current value
Resolution
Refer to
[7-9 Range for Voltage Setting and Crrent Setting].
Unit
A
Format
IGET
Return
example
IGET=0.02345
⇒
For A in Unit, output 23.45mA
STS
Command
Returns Unit state.
Format
STS
Return
(Status)
Return
example
CO LO CV
⇒
Output state, Local control, CV mode
CF RM CC OVP
⇒
Output cutoff, Remote control, CC mode, Overvoltage protection
Status
Output state
Control mode
Operational
mode
Error status
(Output when an error occurs)
CF
OFF
LO
Local
CC
CC
mode
OVP
Overvoltage protection
OCP Overcurrent protection
CO ON
RM
Remote
CV
CV
mode
OTP
Overtemperature
protection
ACF
AC input voltage
abnormality
Remarks
・
Either of CF / CO, LO / RM, or CC / CV is always output.
・
All errors that have occurred will be returned.
・
A space (20
H
) is output to separate each status.