Maxedia 4
AC Power
For protection from electric shock , the Maxedia must be grounded (earthed). The AC mains
supply must be fitted with a current overload circuit break er or fuse and ground-fault (earth-fault)
device.
The Maxedia accepts 100 - 240 VAC nominal, 50/60 Hz. Do not operate the Maxedia on supply
voltages outside this range. The Maxedia IO Box has a primary fuse that is rated 6.3 A, 250 V slow-
blow, high capacity. Disconnect the device from power before changing the fuse. Replace only with a
T 6.3 AH 250 V fuse.
No user-serviceable parts inside.
To apply power, set the power switch to the
I
position.
Power Supply
The Maxedia comes with an auto-sensing, auto-ranging switch-mode power supply. Manual
adjustments to the main voltage and frequency are not necessary as the Maxedia automatically
adapts.
Power Connection
For protection from electric shock , the Maxedia must be grounded (earthed). The AC mains
supply must be fitted with a current overload circuit break er or fuse and ground-fault (earth-fault)
device.
Connect the Maxedia directly to AC power. Do not connect it to a dimmer system. Doing so may
damage the system.
The Maxedia IO Box's 3 AC power output connectors provide a total of 6.3 A maximum. The voltage
at these connectors is the same as the voltage applied to the AC power input connector. Use the
power output connectors only to connect low-power devices such as the 19" Maxedia computer,
external monitors and ethernet switches.
Power Cables
A power cable without a power connector is suppled. Only replace this cable with one of the following
types:
SVT, 18 AWG x 3 - 16 AWG x 3
SJT, 18 AWG x 3 - 14 AWG x 3
H05VV-F, 3G 0.75 - 1.5
4V-75, 250/440 V, 3G 0.75 - 1.0
227 IEC53 (RVV), 300/500 V, 3G 0.75 - 1.5
A 3-prong power plug with live, neutral and ground (earth) pins rated 250 VAC, 10 A minimum must be
installed on the power cable following the plug manufacturer's instructions. Use a power plug of the
approved type for your region. For example:
USA: NEMA 5-15 A
Europe: CEE or Schuko
United Kingdom: UK BSI 13 A
Denmark: SEV
Содержание Maxedia 4
Страница 1: ... 2010 Martin Professional A S Maxedia 4 User Manual DRAFT VERSION ...
Страница 14: ...7 2010 Martin Professional A S Maxedia 4 Connections to the Maxedia are different for each hardware revision ...
Страница 17: ...10 2010 Martin Professional A S Maxedia 4 ...
Страница 36: ...29 2010 Martin Professional A S Maxedia 4 ...
Страница 127: ...120 2010 Martin Professional A S Maxedia 4 ...
Страница 145: ...138 2010 Martin Professional A S Maxedia 4 The Proc Amp tab lets you fine tune the video capture ...
Страница 147: ...140 2010 Martin Professional A S Maxedia 4 ...
Страница 149: ...142 2010 Martin Professional A S Maxedia 4 If Hard Edge is selected no overlapping video will be sent ...
Страница 151: ...144 2010 Martin Professional A S Maxedia 4 ...
Страница 155: ...148 2010 Martin Professional A S Maxedia 4 System Network ...
Страница 159: ...152 2010 Martin Professional A S Maxedia 4 Plugins ...