V.033114
42
M&R Companies 1N 372 Main St. Glen Ellyn, IL 60137 USA
Tel: +630-858-6101 Fax: +630-858-6134
Double Index
Fork Proximity
Switch
The
Double Index Fork
Proximity switch is
mounted to the index base near the load and
unload stations and is positioned so that it reads
the double index fork when the double index fork
is retracted.
When the
Double Index
proximity switch reads
the double index fork, the indicator changes to red.
This confirms the operation of the
Double Index
proximity switch.
If the indicator does not change to red when this
proximity switch is reading the
Double Index
fork,
then the operation of the proximity switch and/or
the cables may be faulty. Inspect and/or replace
the proximity switch and/or cables to correct the
problem.
Home Post
Proximity
Switch
The
Home Post
proximity switch is used during
the initial installation and setup of your press, or
when ever the servo drive assembly or
components have been replaced. This proximity
switch is not used during normal operation. The
switch is located on the left side of the index drive
assembly.
When the
Home Post
proximity switch reads the
index drive assembly, the indicator changes to
red. This confirms the correct operation of the
Home Post
proximity switch.
If the indicator does not change to red when this
proximity switch is reading the Index drive
assembly, then the operation of the proximity
switch and/or the cables may be faulty. Inspect
and/or replace the proximity switch and/or cables
to correct the problem.
Other Tests
To access the
OTHER TESTS
press the
OTHER
TESTS
button on the
HARDWARE TEST
menu
screen.
The
OTHER TESTS
menu displays control
elements such as
Emergency Relay
,
T-Shirt
Sensor
,
Air Pressure
and
HEAD PRINT
BUTTONS
. To the right of the control elements
are indicators which display either
OFF
or
ON
. As
each of the control elements is activated the
indicator to the right displays an
ON
indication.
This confirms the operation of the control element.
For example, if you disconnect the Yellow Cycle
Interruption cords, the indicator to the right of
Yellow Cord displays an
OFF
indication.
Press the
Tests
button to return to the