V.033114
M&R Companies 1N 372 Main St. Glen Ellyn, IL 60137 USA
25
Tel: +630-858-6101 Fax: +630-858-6134
Index
Index
dwell time is the time interval during
automatic operation in which the system operator
may load and/or unload garments. This time
interval starts after the index table has reached the
fully raised position at the conclusion of the index
motion, and ends with the start of the index table
start cycle.
To adjust the
Index
dwell time, press the data
entry cell to the right of
Index
; a numeric keypad is
displayed. Enter the dwell time in seconds and
then press
Enter
. The maximum
Index
dwell time
is 20 seconds and the minimum is 0 seconds.
Revolver
Sequencing
Program
U.S. Patent
No. 5,595,113
The M&R Revolver program is used to program
selected print heads to either print or flash in
multiple cycles with the use of only one flash cure
unit.
To access the
Revolver
menu, press the
Revolver
button on the
Options
screen.
Revolver Mode
On/Off
Enter Program
The button to the right of
Revolver Mode
displays
either
On
or
Off
. To change between
On
and
Off
mode press the button. Press the button so
On
is
displayed to program or operate in the
Revolver
Mode.
After programming the indexer and print heads,
press the
Enter Program
button to store the
program in the PLC memory.
Revolution
Pallet No.
Revolution
allows the selection of up to 10
different revolutions to be programmed for print,
flash operation within the Revolver program. Press
the data entry cell to the right of
Revolution
; a
numeric keypad is displayed. Enter a number from
1 to 10 and then press
Enter
.
The
Pallet No.
provides a visual indication of how
many pallets are entered in the program sequence
for each revolution of the indexer. The numerical
indication counts down as the press progresses
through the Revolver Program.