V.033114
30
M&R Companies 1N 372 Main St. Glen Ellyn, IL 60137 USA
Tel: +630-858-6101 Fax: +630-858-6134
Mega-Stamp
Down Time
Mega-Stamp
Manual Test
Down Time
is used to select the amount of time
that the
Mega-Stamp
heat platen is down in
contact with the foil and garment. To adjust the
Down Time
, press the data entry cell to the right;
a numeric keypad is displayed. Enter the down
time and then press
Enter
. Your selection for the
Down Time
is displayed in the data entry cell.
Manual Test
is used to confirm communication
between the press and the
Mega-Stamp
unit. To
use, press the
OFF
button to the right of
Manual
Test
. The
Mega-Stamp
heat platen cycles down
and the button indicates
On
.
Midas Loader
Midas-Loader
Enabled
Disabled
Midas
Head Location
Midas
Manual Test
The
Midas Loader
menu selection is used to
control the optional M&R Midas foil loader.
To activate the Midas, press the
Disabled
button
to the right of
MIDAS-LOADER
. The indication
changes to
Enabled
and the Midas is activated.
To deactivate the Midas, press the button again.
Head Location
is used to select the print head in
which the M&R Midas will operate. To use, press
the data entry cell to the right of
Head Location
; a
numeric keypad is displayed. Enter the print head
location where the Midas will be operating and
then press
Enter
.
Manual Test
is used to confirm the
communication between the press and the Midas
unit. Press the
OFF
button to the right of
Manual
Test
. The Midas foil gripper cycles in/out and the
button indicates
ON
.
Press the
Forward
Arrow
to access the next
Mega-Stamp menu screen.
Mega-Stamp/
Midas
This screen visually confirms the operation of the
switches used to control the
Mega-Stamp
and the
Midas
. The screen shows the input signals (green)
and the output signals (red) and whether they are
ON
or
OFF
.
The first menu is
Both Safe
. This menu is
displayed in green so it is an input signal. The
illustration shows the input signal as
OFF
.