Quartz Time
Quartz
controls the time the Quartz Flash heating
elements are on. To adjust the
Quartz
dwell time,
press the data entry cell to the right of
Quartz
; a
numeric keypad is displayed. Enter the time in
seconds and then press
Enter
. The maximum
Quartz Time
is 15 seconds and the minimum is 0
seconds.
A graduated scale provides a visual indicator of
the balance of
Quartz Time
. If the
Quartz
time is
set
for 15 seconds, the graduated scale displays a
solid green line up to the 15 indicator. As the
Quartz Time
counts down the green line retracts
towards the zero indication and the data entry cell
displays the remaining
Quartz Time
. When the
Quartz Time
reaches zero, the Quartz heating
elements turn Off.
Quartz
Location
To select a print head to operate as a quartz flash
cure station, first place the
FRONT/REAR
switch
for that particular print head on the main control
panel in the
FRONT
position. Now press the
Enter
button to the right of
Quartz
.
Press the print station number to operate as a
quartz flash cure station. After you press the print
station number the indication changes to green
and displays a vertical line for
On
. If you press the
print station number again, the indication changes
back to red and displays a zero for
Off
.
To select any print station to operate as a Quartz
Flash station, press the
In Any Head
button.
Press the
Back Arrow
button in the lower right
corner to return to the previous screen. The gray
indicator below the print head on the screen now
displays a letter
Q
confirming that the print head
will now operate as a quartz flash cure station.
Press the
Back Arrow
to return to the previous
screen.