V.033114
20
M&R Companies 1N 372 Main St. Glen Ellyn, IL 60137 USA
Tel: +630-858-6101 Fax: +630-858-6134
can record the production levels and use this
information to estimate future production times for
this particular job.
Press the
Back Arrow
to return to the
MENU
screen.
Timers
Index
Press the
Timers
button on the
Menu
screen. The
Timers menu contains five menu items:
Index
,
Flash
,
Quartz
,
Delay
and
Preheat
.
Index
dwell time is the time interval during
automatic operation in which the system operator
may load and/or unload garments. This time
interval starts after the index table has reached the
fully raised position at the conclusion of the index
motion, and ends with the start of the index table
start cycle.
To quickly adjust the time in 0.5 second
increments, press the
plus
or
minus
buttons.
To adjust the
Index
dwell time, press the data
entry cell to the right of
Index
;
a numeric keypad is
displayed. Enter the dwell time in seconds and
then press
Enter
. The maximum
Index
dwell time
interval is 20 seconds and the minimum is 0
seconds.
Flash
Flash
controls the dwell time of the index table in
the raised position (Flash Cure position). To adjust
the
Flash
dwell time press the data entry cell to
the right of
Flash
; a numeric keypad is displayed.
Enter the time in seconds and then press
Enter
.
The maximum
Flash
dwell time is 20 seconds and
the minimum is 0 seconds.
To quickly adjust the time in 0.5 second
increments, press the
plus
or
minus
buttons.
Quartz
Quartz
controls the dwell time of the index table in
the raised position (Flash Cure position). To adjust
the
Quartz
dwell time press the data entry cell to
the right of
Quartz
; a numeric keypad is displayed.
Enter the time in seconds and then press
Enter
.
The maximum
Quartz
time is 15 seconds and the
minimum is 0 seconds.
To quickly adjust the time in 0.5 second
increments,
press
the
plus
or minus buttons.