V.033114
M&R Companies 1N 372 Main St. Glen Ellyn, IL 60137 USA
29
Tel: +630-858-6101 Fax: +630-858-6134
Low Oil
Indexes
Present
Total
The oil level in the oil reservoir for the index servo
drive system is monitored by a sensor which alerts
the operator to insufficient oil for lubrication. The
oil level may be monitored using the
Low Oil
Indexes
menu selection.
Present
displays how many index cycles have
occurred since the low oil sensor detected a low
oil condition.
Total
displays how many total index cycles have
occurred after a low oil condition since the press
was first put into service.
Press the
Back Arrow
to return to the previous
menu screen.
Mega-Stamp
Mega-Stamp
is the M&R optional foil application
system used with the press.
To access the
Mega-Stamp
menu selection,
press the
Mega-Stamp
button on the
Options
menu screen.
Mega-Stamp
Mega-Stamp
Head Location
The
Mega-Stamp
menu includes control menus
used on both the M&R Mega-Stamp and the M&R
Midas foil loading system. The four
Mega-Stamp
menu selections are displayed in red and the three
Midas menus are displayed in yellow.
To activate or deactivate the
Mega-Stamp
, press
the
Disabled
button to the right of
Mega-Stamp
.
The indication changes to
Enabled
and the
Mega-
Stamp
is activated. To deactivate the
Mega-
Stamp
, press the button again.
Head Location
is used to select the print head in
which the M&R
Mega-Stamp
will operate.
To use, press the data entry cell to the right of
Mega-Stamp
; a numeric keypad is displayed.
Enter the print head location where the
Mega-
Stamp
will be operating and then press
Enter
.