V.033114
36
M&R Companies 1N 372 Main St. Glen Ellyn, IL 60137 USA
Tel: +630-858-6101 Fax: +630-858-6134
right of
Spray Every
; a numeric keypad is
displayed. Enter the number from 1 to 99 and then
press
Enter
. Your selection for
Spray Every
is
now displayed in the data entry cell.
Front Delay (3)
Front Delay
permits the system operator to
program a time delay interval, in hundreds of a
second, before activation of the Annamister
system. The maximum setting is 1 second and the
minimum setting is 0.01 second. This setting will
vary depending on the pallet size and press
speed. However in most cases this setting will be
less than 0.1 second.
To enter a number for the
Front
Delay
, press the
data entry cell to the right of
Front Delay
; a
numeric keypad is displayed. Enter the number
from 0.01 to 1 and then press
Enter
. Your
selection for
Front Delay
is displayed in the data
entry cell.
Front Duration
(4)
Front Duration
permits the operator to program
the time interval, in hundreds of a second, in which
the M&R Annamister applies adhesive to the
pallets. The minimum setting is 0 and the
maximum setting is 1 second. This setting varies
depending on the surface area (size) of the pallet
and the press speed. In most cases the setting is
set between 0.2 and 0.4 seconds.
To enter a number for the
Front Duration
, press
the data entry cell to the right of
Front Duration
; a
numeric keypad is displayed. Enter the number
from 0.2 to 0.41 and then press
Enter
. Your
selection for
Front Duration
is displayed in the
data entry cell.
Rear Delay (5)
Rear Duration
(6)
Rear Delay
operates in the same manner as
described for
Front Delay
.
The
Rear Duration
operates like the
Front
Duration
.
Note: Rear Delay and Rear Duration will not be
displayed if the Revolver Flash is activated in the
Service Data menu. Contact M&R Technical
Support for assistance in accessing these control
menus.