Fig. 3-3
Detail pendulum impact test; figure shows a deformation
of 0.5 mm at an impact force of 1000 N
3.3.3 Dynamic front impact test
This test demonstrates the dynamic impact force of the wing during
operation (closing).
The tests are determined according to the gate standard
DIN EN 12453 with the prescribed measuring instrument .
The test was made in three different positions (nearly completely
driven out, approx. half driven out and little driven out). The auto-
matic reversing mechanism has been activated during the tests
The closing times of the individual wing types (PUR, Acrylic, Tele-
scopic 280 mm and telescopic 200 mm) have been adapted in such
a way, that the collision force amounts to a max. value of 400 N
F