Functional description of MBC110
581E,5721/ 07/2006 MPR112_1
page 34/72
Version: 01
8.2.3 Default function of outputs
The function of relay 1 is not alterable because this output is also
used as feedback for power supply loss.
Output
Default function
Relay 1
Global alarm output / Voltage failure
Relay 2
Ready for passage left
Relay 3
Ready for passage right
Relay 4
Counting pulse output
Relay 5
Inhibit card reader left
Relay 6
Inhibit card reader right
MOSFet-output 1
GED left red
MOSFet- output 2
GED left green
MOSFet- output 3
GED right red
MOSFet- output 4
GED right green
Relay 1 = Global Alarm message / alarm output
Global alarm output, alarm permanent as long as the failure ap-
pears.
Failure description:
- Impact
detection
-
Emergency input activated (inverted)
-
CAN communication with output stage disturbed
-
Hardware failure output stage
-
Software failure output stage
-
Voltage failure
Содержание MPR 112
Страница 25: ...Electrical Connection 581E 5721 07 2006 MPR112_1 page 25 72 Version 01 Fig 5 4 Wiring diagram 2...
Страница 57: ...Functional description of MBC110 581E 5721 07 2006 MPR112_1 page 57 72 Version 01 Fig 8 5 Logic Module MBC 110...
Страница 72: ...page 72 72 www MagneticPedestrian com 800 878 7829 Sales MagneticPedestrian com...