Functional description of MBC110
581E,5721/ 07/2006 MPR112_1
page 46/72
Version: 01
8.4.4 Mode 2: Exit Mode
If IN5 is activated (contact closed) and IN4 disabled (contact open)
the barrier allows passage only from right to left (exit). Any opening
inputs on IN 4 are ignored.
Direction left (entry):
-
Barrier End Display shows GREEN ARROW
-
Opening input Left is activated
-
Directional beams are active and evaluated based on the walk-
through direction
-
r.f.p.l. is off
-
I.c.r.l. is on
Direction right (exit):
-
Barrier End Display shows GREEN ARROW
-
Opening input Right enabled
-
Directional beams are active and evaluated based on the walk-
through direction
-
r.f.p.r. is being controlled
-
I.c.r.r. is off
In case a person is trying to walk through the barrier from an incor-
rect direction, the controller immediately activates an alarm output
and the barrier remains closed. This alarm turns off after 2 s when
the person backs out of the barrier.
If a person walks into the barrier from the controlled direction with-
out presenting a valid identification within 5 seconds, the controller
activates an alarm output as well. The alarm turns off after 2 s when
the person backs up, or presents the valid identification to the card
reader.