![Magnetic Autocontrol MPR 112 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/magnetic-autocontrol/mpr-112/mpr-112_operation-and-installation-instructions-manual_3588816004.webp)
Delivery
581E,5721/ 07/2006 MPR112_1
page 4/72
Version: 01
1.
Delivery
1.1 Scope of delivery
1 x Retractable barrier (quantity and models depend on lane layout)
4 x Mounting hardware
2 x Keys
1 x Documentation
1.2 Technical data
MODEL
TECHNICAL DATA
Dimens.
unit
MPR-112A/B-A2X0
MPR-112A/B-A3X1
MPR-112A/B-A2X2
Voltage
VAC
115-240
115-240
115-240
Frequency
Hz
50-60
50-60
50-60
Gate open
power consumption /
current
W / A
40 / 0,3
35 / 0,3
80 / 0,47
Gate closed
power consumption /
current
W / A
45 / 0,3
35 / 0,3
117 / 0,7
Max. peak in operation
(30 ms)
W / A
140 / 0,85
140 / 0,85
654 / 3,4
Duty Cycle
%
100
100
100
Protection class
IP
32
32
32
Opening time
ms
400
300
3
600
Closing time
ms
400
300
4
600
Length
mm
1300
1300
1300
Width
mm
200
250
280
Hight
mm
1035
1035
1035
3
Acrylic-flap
ms
-
350
-
4
Acrylic-flap
ms
-
350
-
The data given in the table can deviate due to technical changes! All current values refer to a mains voltage of
240 V.