Functional description of MBC110
581E,5721/ 07/2006 MPR112_1
page 39/72
Version: 01
A short beep is also sent out in following situations:
•
If the gate is ready for passage
•
After a passage has been completed
DIP 2
Buzzer
Off Buzzer
off
On Buzzer
on
8.3.3 DIP- switch 3 and 4: Safety delay time
It is the additional time after receiving the closed command. After
the safety delay time the wings close.
The safety delay time is adjustable in 4 steps:
DIP 3
DIP 4
Safety delay time
Off Off
0
s
On Off
1
s
Off On
2
s
On On
3
s
8.3.4 DIP- switch 5 and 6: Hold open time
The hold-open time is a defined period during the MPR is ready for
passage after receipt of an opening pulse and nobody enters for
passage. After this period expire the MPR locks (if nobody walks
through).
The hold-open time can be adjusted in 4 steps:
DIP 5
DIP 6
Hold open time
Off Off
2
s
On Off
4
s
Off On
6
s
On On
12
s
8.3.5 DIP- switch 7: Request of the Software Version
If this function is activated during operation mode, the current soft-
ware version is indicated in circular mode at the 7 segment displays.