Functional description of MBC110
581E,5721/ 07/2006 MPR112_1
page 41/72
Version: 01
8.3.9 DIP- switch 12: Behaviour after impact detection
Determines the behaviour after an impact detection.
DIP 12
Behaviour after impact detection
Off
Wings are still trying to close (no retract)
On
Wings open immediately and try to close with reduced
speed
8.3.10 DIP- switch 13: Reverse during closing
After receiving the close signal the wings try to close. If the PE
beams are covered before receiving the closed position, the wings
can either retract or continue closing operation.
DIP 13
Retract
Off
Wings continue the closing procedure
On
Wings open and stay open until blocked PE beams are
cleared
8.3.11 DIP- switch 14 - 15: Wing-Type
Determine the MPR wing type and aisle width
Aisle width
Aisle width
Aisle width
DIP 14
DIP 15
Standard 250 mm
housing
Telescopic 2
0
0
mm housing
Telescopic 280
mm housing
Off
Off
Acrylic 520 mm
520 mm
960 mm
On
Off
Soft 520 mm
560 mm
900 mm
Off
On
Not used
600 mm
Not used
On
On
Not used
Not used
Not used
Содержание MPR 112
Страница 25: ...Electrical Connection 581E 5721 07 2006 MPR112_1 page 25 72 Version 01 Fig 5 4 Wiring diagram 2...
Страница 57: ...Functional description of MBC110 581E 5721 07 2006 MPR112_1 page 57 72 Version 01 Fig 8 5 Logic Module MBC 110...
Страница 72: ...page 72 72 www MagneticPedestrian com 800 878 7829 Sales MagneticPedestrian com...