Functional description of MBC110
581E,5721/ 07/2006 MPR112_1
page 38/72
Version: 01
Error codes with automatic reset function will be displayed for fur-
ther 10 seconds after the error is rectified. But as long as the error
exists as long the error code is displayed.
All other errors will cause pedestrian barriers to be set out of opera-
tion. The error code will be displayed permanently until the new start
of the controller after rectification of the fault.
8.3 Parameter settings
The following functions are settable via the DIP switches.
NOTE!
Modifications of the DIP switch settings will only be processed after
power on (except for DIP 7)
8.3.1 DIP-switch
1: Pulse Storage
If the pulse storage is switched off, the MPR will be opened due to a
pulse released at one of the both opening inputs. Any following
pulses will be ignored as long the MPR remains still open.
If the pulse storage is activated, several opening pulses can be
stored. The pedestrian gate stays open, until all stored pulses are
executed and the pulse store is cleared. Each passage will reduce
the pulse by 1.
DIP 1
Pulse Storage
Off No
pulse
stored
On
Up to 5 pulses can be stored
8.3.2 DIP- switch 2: Buzzer
The buzzer sends out permanent alarm signals in following cases:
•
During the homing process
•
In case of a wrong-way intrusion
•
In case of a hardware or software error
•
In case of a break-through attempt
•
If a PE beam is blocked for more than 30 seconds