Section 8 – RCP Programming (Continued)
96
Enter the Access Code (Must be set for system to work):
Screen switch operation.
The screen switches are labeled from left to right, “A” and “B”. They are numbered from left to right 1 to 8. The black
rectangle to the bottom is “OFF” or “0,” and the green rectangle to the top is “ON” or a “1”. Clicking the grey rectangle
will cause the switch to toggle. There is also a box which shows the decimal value of the binary number entered. Some
receiver types will show the access code as a decimal number. That number can be entered here.
See Section 7.1. Access Code Programming for details on access code programming. There should be a label either on the
receiver or the old transmitter showing the access code - it should be numbered A1 through A8 and B1 though B8. Find
this number and tap the respective switches on the screen. If you cannot find a label with access code information, copy the
information directly from the access code dip switches in the transmitter or receiver. Please make sure to match the
designation and switch position as they do vary from model to model.
Control Configuration (2 speed only)
The transmitter can be programmed for custom control configurations using the control function. These configurations
correspond to the wiring diagrams in Section 6 of the inteleSmart receiver manuals. Simply select the setting that matches
the title of the desired wiring diagram.
Main/Aux (2 speed only)
This menu will only appear if a special control configuration (above) is not selected. This menu defines the function of the
auxiliary buttons. The “Aux Only” setting is used for a standard three motion crane. The top three auxiliary buttons will
be active. “Motor” is used for a four motion crane. The button just above the E-stop will serve to select between the main
and aux. motors. The tandem check box will appear when this is selected. If you want to be able to operate both hoists at
the same time, check the tandem option. “Select” allows the system to operate with select relays. As before, check the
tandem option if you want to operate both hoist/trolleys together. The invert check box will also appear. This function is
rarely used and this box should normally not be checked. Consult Field Service (1-800-288-8178) if you are unsure if you
need this function.
Multibox (Optional; skip if you do not wish to use the Multibox feature):
Do not use on InteleSmart Receivers.
Use Group Code feature
see InteleSmart Receiver Manual
.