Section 7 - Programming (Continued)
54
NOTE
FOR THE MEMBRANE, PENDANT TRANSMITTER AND RECEIVER. DO NOT USE A PENCIL TO
TOGGLE THE SWITCHES. THE LOOSE GRAPHITE FROM THE PENCIL CAN DAMAGE THE
SWITCH.
WARNING
TWO OPERATIONAL TRANSMITTERS WITH THE SAME ACCESS CODES OPERATING AT THE
SAME TIME IS A DEFINITE SAFETY HAZARD. FAILURE TO FOLLOW THIS WARNING COULD
RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT.
7-1.2.
Changing Transmitter Access Codes.
7-1.2.1.
telePilot
Access Code Programming.
For detailed instructions on setting parameters including access codes see Section 7-8.
teleP
ilot
Programming.
7-1.2.2.
Membrane Transmitter Access Code Setting.
Open the back battery door and take out the batteries as a safety precaution.
Remove the 6 screws on the front cover. Lift out switch-pad, logic board and turn logic board over.
Locate the dip switches marked “A” and “B”. See Figure 8-3. Membrane Transmitter M/C Module
E10635. With a pen or pointed object toggle the switches to match the Access Code on the receiver. A dot
on the switch diagram means that switch position is ON. For Membrane transmitters the access code
positions A1-A4 can be accessed through the battery compartment.
Reassemble unit; replace the batteries and test.
7-1.2.3.
Pendant Transmitter Access Code Setting.
Open the back battery door and take out the batteries as a safety precaution.
Remove the 8 screws on the front cover. Turn transmitter over and remove back cover.
Locate the dip switches marked “A” and “B”. See Figure 8-6. Pendant Transmitter M/C Module E10636.
With a pen or pointed object toggle the switches to match the Pendant Transmitter Code Diagram on the
door of the receiver. A dot on the switch diagram means that switch position is ON.
Reassemble unit; replace the batteries and test.