Section 7 - Programming (Continued)
60
For Membrane transmitters the Access code positions A1-A2 can be accessed through the battery
compartment. The Pendant Transmitter requires the back to be removed.
See Table 7-1. Multibox Switch Settings below for appropriate settings for both the transmitters and
receiver(s).
Receiver (See Figure 9-1).
Transmitter (Membrane and Pendant only).
SW3 Switch
Maximum
Access Code Switch
Settings
Transmitters
Settings
3-1 3-2 3-3
OFF OFF OFF
1
First
Access
Code
ON
OFF
OFF
2
First Access Code + 1 bit
OFF
ON
OFF
3
First Access Code + 2 bits
ON
ON
OFF
4
First Access Code + 3 bits
OFF
OFF
ON
5
First Access Code + 4 bits
ON
OFF
ON
6
First Access Code + 5 bits
OFF
ON
ON
7
First Access Code + 6 bits
ON
ON
ON
8
First Access Code + 7 bits
7-4.
Custom Programming.
7-4.1.
Receiver Programming Options.
The following parameters are programmable in the receiver: (See below for details).
Auto Alarm – Sounds alarm on turn on.
E-STOP Alarm – Sends Alarm on E-STOP.
Single or 2-speed system – Assigns outputs.
Latching of auxiliary relays – Up to two relays.
Time-out-timer
disable.
Number of Multibox transmitters.
7-4.2.
Transmitter Programming Options.
The following parameters are programmable in most transmitters: (See Sections 7-6., 7-7. and 7-8.
Membrane, Pendant and
tele
Pilot
Programming for details).
Switch Position – Hoist, Trolley Etc.
Timer-out-timer
operation.
Modes – Single speed switch grouping.
Crane configuration -
Tandem disable – Eliminates “both”
Select invert – Inverts the select function.
Table 7-1. Multibox Switch Settings.
Figure 7-3. SW3 Receiver Multibox Dip
Switches
ON
8 7 6 5 4 3 2 1
OFF
8 7 6 5 4 3 2 1