background image

Flow Measurement

SITRANS F M

Transmitter TRANSMAG 2 with sensor 911/E

3/104

Siemens FI 01 · 2014

Overview

 

SITRANS F M TRANSMAG 2 with the SITRANS FM 911/E sensor 
is a pulsed alternating field magnetic flowmeter where the mag-
netic field strength is much higher than conventional DC pulsed 
magnetic flowmeters. 

Benefits

• Wide range of sizes DN 15 to DN 1000 (½" to 40")

• Broad range of liner and electrode materials for extreme pro-

cess medias

• Fully welded construction provides a ruggedness that suits 

the toughest applications and environments.

• Automatic reading of SmartPLUG for easy commissioning

• Simple menu operation with two-line display

• Comprehensiv self-diagnostic with selfmonitoring and internal 

simulation

Application

The main applications of the SITRANS F M transmitter 
TRANSMAG 2 can be found in the following sectors:

• Pulp and Paper industry

• Mining industry

The patented pulse alternating field technology is ideal for diffi-
cult applications like:

• High concentrated paper stock > 3 %

• Heavy mining slurries

• Mining slurries with magnetic particles.

• Low conductive medias 

S/cm (0.1 

S/cm depending on 

medium)

Design

• Available for remote mounting

• PROFIBUS PA (profile 2.0) / HART communication

• Analog output and digital outputs for pulses, device status, 

limits, flow direction, frequency output

Mode of operation

The flow measuring principle is based on Faraday’s law of elec-
tromagnetic induction according to which the sensor converts 
the flow into an electrical voltage proportional to the velocity of 
the flow.

Function

The TRANSMAG 2 is a microprocessor-based transmitter with a 
build-in alphanumeric display in several languages. The trans-
mitters evaluate the signals from the associated electromagnetic 
sensors and also fulfil the task of a power supply unit which pro-
vides the magnet coils with a constant current.

The magnetic flux density in the sensor is additionally monitored 
by reference coils.

Further information on connection, mode of operation and instal-
lation can be found in the data sheets for the sensors.

Displays and keypad

Operation of the transmitter can be carried out using:

• Keypad and display unit

• HART communicator

• PC/laptop and SIMATIC PDM software via HART communica-

tion

• PC/laptop and SIMATIC PDM software using PROFIBUS PA 

communication

 

HART communication

 

PROFIBUS PA communication

Operating and 
display panel

PC/ 
laptop

Coupling 
module

HART 
communicator

RS 232

min. 230 Ω

Transmitter with
PROFIBUS PA interface

Coupler with
power supply

Bus 
term.

Master

PROFIBUS DP

PROFIBUS PA

.......

T

+

FI01_2014_en_Kap03.book  Seite 104  Montag, 11. November 2013  4:45 16

© Siemens AG 2013

 

 

icenta Controls Ltd 

Tel: +44 (0)1722 41

    Fax: +44 (0)1722 

    e: [email protected]    www.icenta.co.uk 

Содержание TRANSMAG 2

Страница 1: ...ce status limits flow direction frequency output Mode of operation The flow measuring principle is based on Faraday s law of elec tromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to the velocity of the flow Function The TRANSMAG 2 is a microprocessor based transmitter with a build in alphanumeric display in several languages The trans mi...

Страница 2: ...put with PC cou pling module or HART communi cator Protocol HART version 5 1 Digital output Signal Output Configurable as active or passive signals Active signal 24 V DC 24 mA Ri 170 Passive signal Open collector max 30 V DC 200 mA Output configuration Pulse Pulse significance 5000 pulses s Pulse width 0 1 ms Limit frequency 10000 Hz Limits Limits for flow and quantity flow direction alarm Digital...

Страница 3: ... Remote version Transmitter must be connected to sensor using shielded cable Maximum cable length 100 m 328 ft Housing Die cast aluminum painted Displays and keypad General display LCD backlid two lines with 16 characters each Multi display for Flow totalizer flow velocity Keypad 4 keys for entering parameters Power supply corresponding to rating plate AC supply 100 250 V AC 15 47 63 Hz Power cons...

Страница 4: ...C01 Cover for sensor cable and gasket Die cast aluminum with corrosion resistant Basic Polyester powder coating min 60 m 7ME5933 0AC02 Cover for mains supply communication Die cast aluminum with corro sion resistant Basic Polyes ter powder coating min 60 m 7ME5933 0AC03 Safety clamp for electronic cover with glass plate 7ME5933 0AC01 7ME5933 0AC06 M20 cable gland set for power and output connec ti...

Страница 5: ...4 mA Ri 170 Ω active passive Passive open collector max 30 V DC 200 mA 0 4 20mA Load 600 Ω max 15 V Digital output 1 Passive open collector max 30 DC 100 mA Power supply Transmitter Power supply L N PE conductor Sensor Sensor connection Digital output 2 Relay NC NO max 5W 50 V DC 200 mA or Digital input High 11 30 V DC Low 30 5 V DC green yellow white brown Ref 2 Ref 1 Reference coil Electr 2 EL 2...

Страница 6: ...ial Defined via the Order code Protection rings for liners Function To protect the edges of liners from abrasion e g gravel sand etc Used mainly with soft rubber liners and for PTFE liners at high temperatures from 100 to 150 C 212 to 302 F Contact with medium Yes please always check resistance to measured medium Material Stainless steel AISI 316Ti 1 4571 optionally Hastelloy C276 2 4819 Material ...

Страница 7: ...inal diameter Nominal pressure Permissible media Category DN inch PN MWP psi 15 25 1 40 580 Gases fluid group 1 and liquids fluid group 1 Article 3 3 200 300 8 12 10 145 Gases fluid group 1 and liquids fluid group 1 II 65 250 2 10 16 232 Gases fluid group 1 and liquids fluid group 1 II 40 100 1 4 40 580 Gases fluid group 1 and liquids fluid group 1 II 350 1000 14 40 10 145 Gases fluid group 1 and ...

Страница 8: ...m 4 Tantalum 5 Cable glands terminal box Metric Polyamide terminal box 1 NPT Polyamide terminal box 2 Selection and Ordering data Order Code Additional information Please add Z to Article No and specify Order code s and plain text Two earthing grounding electrodes made of stainless steel AISI 316Ti 1 4571 A02 Two earthing grounding electrodes made of Hastelloy C276 2 4819 A04 Two earthing groundin...

Страница 9: ... Selection and Ordering data Article No Order code SITRANS F M electromagnetic flowmeter Earthing rings for flow sensor 911E per unit 7 ME 5 9 0 2 7777 777 Liner Hard rubber soft rubber 1 Novolak 7 PTFE 0 Nominal diameter Mat no 1 4571 316 Ti DN 15 A A DN 25 1 C A DN 40 1 E A DN 50 2 F A DN 65 2 GA DN 80 3 H A DN 100 4 J A DN 125 5 K A DN 150 6 L A DN 200 8 MA DN 250 10 N A DN 300 12 P A DN 350 14...

Страница 10: ... 0 17 64 8 5 18 74 11 5 25 35 25 0 55 12 26 57 32 27 59 53 28 61 73 34 74 95 38 83 78 68 149 9 81 178 6 Nominal diameter DN 300 DN 350 DN 400 DN 450 DN 500 DN 600 DN 700 DN 750 DN 800 DN 900 DN 1000 12 14 16 18 20 24 28 30 32 36 40 Build in length L1 Hard rubber version Linatex soft rubber version 500 19 68 550 21 65 600 23 62 650 25 59 650 25 59 780 30 71 910 35 83 1040 40 95 1170 46 06 1300 51 1...

Отзывы: