Disassembly
The following are step-by-step instructions for the disassembly of the Solo. Depending on the
component being replaced, not all steps of the disassembly procedure will need to be performed.
As the disassembly involves electronic components, the work area must be clean and have
appropriate anti-static measures in place with anti-static mats, pads, wrist-straps, and any other
appropriate anti-static equipment. A #2 Phillips screwdriver (with magnetic tip) is the primary tool
required for disassembly and re-assembly of the Solo.
Note: All disassembly and reassembly should be performed with the battery packs disconnected
or removed. Please refer to Figure 7 of this manual showing the exploded view of all meter
components.
9.5
Disassembly of Lower Coin Chute Assembly
1)
Separate the coin chute assembly from the main meter frame.
i)
Disconnect ribbon cable that electrically connects the coin chute assembly to the
main board by depressing the two eject tabs on the MCB connector.
ii)
While supporting both the coin chute assembly and the main meter frame, pull out
the quick release pin located on the linkage assembly. This will separate the main
meter from the coin chute assembly.
•
Figure 24 - Quick Release Pin
iii)
Unscrew the lower two captive screws found at the lower back of the coin chute
assembly. Note that these screws are self-retaining and will remain on the main
frame when unscrewed from the coin chute front.
48
Содержание Guardian SOLO
Страница 1: ...JJ12 001 v1 5 February 2013...
Страница 4: ......
Страница 10: ......
Страница 77: ...MacKay Guardian Solo Operation and Maintenance Guide v 1 5 Notes 67...
Страница 78: ...MacKay Guardian Solo Operation and Maintenance Guide v 1 5 Notes 68...
Страница 79: ...MacKay Guardian Solo Operation and Maintenance Guide v 1 5 69...